pyrotec general no. 2/4


Pyrotec
Model

Capacity

Dimensions (m)

Chimney
internal
diameter
(m)

Manual
loading
door size
(m)

Weight
(Kg)

Kg/Hr

Thermal
KCal/Hr

A

B

C

D

E

D20

20

72,220

1.50

0.90

1.20

1.50

8.00

0.250

0.40 x
0.40

1,000

D40

40

144,440

1.80

1.00

1.30

1.50

8.00

0.275

0.50 x
0.50

1,700

D50

50

180,550

2.00

1.15

1.45

1.70

8.00

0.300

0.50 x
0.50

1,800

D60

60

216,660

2.40

1.30

1.60

1.85

8.00

0.350

0.50 x
0.50

2,500

D80

80

288,880

2.60

1.45

1.75

1.90

8.00

0.400

0.60 x
0.50

3,500

Note :-

Burning capacities are based on waste having a calorific value of 3,611 KCal/Kg.
Our specifications are subject to alteration due to our continuous product improvement policy.



design

The Pyrotec D is designed to burn classified documents, computer paper, cheques and bills in a secure, clean and environmentally safe manner without any support fuel, reducing the document to an illegible ash. This model is suitable for banks, military camps, embassies, offices, schools, Government departments, police and lottery companies.

models

D20, D40, D50, D60 and D80.

waste type

Classified paper documents. Paper waste, bank notes and cheques. Calorific value 3,611 KCal/Kg, bulk density 80 to 160 Kg/m³.

construction

Mild steel fabricated construction using 6mm steel plate suitably braced and stiffened, with an outer air cooled security casing.

refractory

Primary chamber - insulation 76mm thick. Secondary chamber - insulation refractory 76mm thick.

firegate

A cast iron firegate will be incorporated into the primary combustion chamber designed to allow agitation of the waste from an externally mounted handle.

fuel

No auxiliary fuel required.

fan

For burning dense computer paper, cheque books or bank notes a combustion air fan with time clock control can be fitted to the incinerator.

finish

Two coats of primer followed by two coats of enamel finish in burgundy.

electricity

220/240 Volt. 1 phase. 50/60Hz - (only when fan fitted).

manual loading

Front mounted hinged opening door complete with security locking hasps.

ash removal door

Located to give access for ash removal from beneath the firegate the ash door is equipped with an ash collection pan on wheels. Additional ash doors allow removal of ash from the secondary chamber all doors are fitted with locking hasps.

chimney

Incinerator mounted manufactured from mild steel and fitted with a spark arrestor.

padlocks

Security padlocks can be supplied and fitted to all loading and ash removal doors.



copyright © 2003, Tectrol SRL.
url :
www.techtrol.net