TECHTROL incineration systems

pyrotec animal no. 3/2

Pyrotec
Model

Capacity

Dimensions (m)

Top
loading
door size
(m)

Ash
door
size
(m)

Auto
loader
size
(m³)

Kg/Hr

Thermal
KCal/Hr

A

B

C

D

E

F

AP150

150

333,750

3.40

3.50

4.40

4.35

2.50

5.40

0.75 x 0.75

0.70 x 0.70

1.5

AP200

200

445,000

3.95

3.50

4.40

4.35

2.50

5.40

0.75 x 0.75

0.70 x 0.70

1.5

AP250

250

556,250

4.20

3.90

4.50

5.00

3.00

5.50

0.75 x 0.75

0.80 x 0.80

2.0/4.0

AP300

300

667,500

4.56

3.90

4.80

5.00

3.00

5.80

0.75 x 0.75

0.80 x 0.80

2.0/4.0

AP400

400

890,000

5.15

4.30

5.00

5.00

3.00

6.00

0.75 x 0.75

0.80 x 0.80

2.0/4.0

AP500

500

1,112,500

5.53

4.55

5.20

5.00

3.50

6.20

0.75 x 0.75

0.80 x 0.80

2.0/4.0

Note :-

Burning capacities are based on waste having a calorific value of 1,000 KCal/Kg.
Our specifications are subject to alteration due to our continuous product improvement policy.



design

The Pyrotec AP is a modern incinerator designed to burn animal and pathological waste in a clean and environmentally safe manner. Recuperating heat from the combustion process within a multi-pass secondary chamber beneath the crematory hearth makes the Pyrotec AP Hot Hearth Incinerator ideal for the incineration of animals, pathological and high moisture content waste. Suitable for animal crematoria, veterinary centres, research companies, abattoirs, agricultural establishments and hospitals. It is equipped with the necessary sophistication of control, secondary chamber volume, manual or automatic loading options and chimney.

models

AP150, AP200, AP250, AP300, AP400 and AP500.

standard

BS3316, 1987 - United Kingdom Environmental Protection Act 1991, PG5/3 or to suit appropriate local legislation. Secondary chamber residence time :- 2.0 seconds at 850ºC.

waste type

Animal waste - calorific value 1,000 KCal/Kg, moisture content 85% - bulk density 700 Kg/m³. Type 4 waste - calorific value 555 KCal/Kg, moisture content 85% - bulk density 700 Kg/m³. Type 3 - calorific value 1,388 KCal/Kg, moisture content 70% - bulk density 500 Kg/m³.

construction

Mild steel fabricated construction using 6mm steel plate suitably braced and stiffened.

refractory

Primary chamber - hot face material 1,400ºC quality 115/150mm thick, backed by 76/150mm of Calcium silicate insulation. Secondary chamber - hot face material 1,600ºC quality 115/150mm thick, backed by 76/150mm Calcium silicate insulation. Crematory hearth - super strength refractory 150mm thick.

fuel

Natural gas, LP gas or 35 seconds fuel oil.

burners

Automatic package burners complete with electric ignition and flame failure control complete with all necessary valves, motors and integral continuous running fan. Temperature controlled to provide optimum combustion conditions, secondary chamber temperatures and fuel economy. Primary chamber - three to four @ 200,000 KCal/Hr on/off control, sized to suit model. Secondary chamber - two to four @ 200,000-350,000 KCal/Hr high/low control, sized to suit model.

fans

All combustion and cooling air is provided by automatically controlled centrifugal fans which provide air to nozzles strategically located throughout the combustion chambers to ensure optimum conditions.

finish

Two coats of primer followed by two coats of enamel finish in burgundy.

control panel

Automatic control system built to IEC Standards incorporating PLC controller, as necessary, providing all automatic plant functions and incorporating the following sequences.

1. Preheat
2. Burn cycle
3. Automatic loading
4. Burndown
5. Cooldown

The control panel will be equipped with an active mimic diagram showing operating status of the plant together with temperature indication of primary and secondary chambers.

monitors

Particulate monitor, Carbon monoxide and Oxygen monitor, Six point chart recorder.

electricity

380/440 Volt. 3 phase. 50/60Hz.

automatic loading

Hydraulically powered automatic fully sequenced ram loader designed to operate in unison with the incinerator operation having programmable time and temperature operating sequence to ensure maximum throughput. Water sprays around the loader throat to quench the ram face following each loading sequence.

top loading

A hydraulically operated sliding top loading door can be provided to allow the top loading of waste utilising a bin hoist and tipping mechanism to handle and load post mortem and very wet waste.

ash removal door

Located to give access for ash removal from the main combustion chamber a refractory lined hinged door with locking handle will be provided, additional ash doors are provided for the secondary chambers.

exhaust system

An induced draught fan system will be employed to overcome system resistance and provide balanced combustion conditions, discharging the exhaust gases into the chimney.

ash removal

Vacuum ash removal with absolute filtration and ash crusher as required can be provided.

chimney

Free standing mild steel chimney built to BS4076 can be supplied to suit site.

wiring

Electrical wiring will be carried out in PVC covered cable, run on cable trays.

fuel piping

Fuel piping between the burners will be completed terminating in a single connection point on the incinerator.